ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL.
INSTALLATION INSTRUCTIONS FOR
CONCENTRIC VENT KIT AOPS7483 & DUAL PIPE FLASHING KIT AOPS7484
ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.
Failure to carefully read and follow all instructions in these instructions could result in death,
personal injury, property damage and/or furnace malfunction.
Installation or repairs made by unqualified persons could result in hazards to you and others.
Installation MUST conform with local codes or, in the absence of local codes, with codes of the
country having jurisdiction.
The information contained in these instructions is intended for use by a qualified service
technician familiar with safety procedures and equipped with the proper tools and test
instruments.
ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.
Failure to follow this warning could result in death, personal injury, property damage and/or
equipment damage.
Turn OFF gas supply at manual gas valve before turning OFF electric power supply and
starting installation.
Turn OFF electric power supply at disconnect switch or service panel before starting
installation.
CARBON MONOXIDE POISONING, AND PROPERTY DAMAGE HAZARD.
Failure to follow this warning could result in death, personal injury, property damage and/or
equipment damage.
This kit is to be used for terminating condensing Category IV vent furnaces. DO NOT use kit
to terminate Category I, II, or III vent furnaces.
MG-507
ECN 5059-MA
- 1 -
Vue de la page 0
1 2 3 4 5 6 ... 12 13

Résumé du contenu

Page 1 - MG-507

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. INSTALLATION INSTRUCTIONS FOR CONCENTRIC VENT KIT AOPS7483 & DU

Page 2

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. 8. Apply PVC cement to pipe end of the 2” pipe assembly (FIG-10) and

Page 3 - UNIT OPERATION HAZARD

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. - 11 -

Page 4

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. INSTALLING TWIN 2” DIAMETER PVC PIPES THRU THE ROOF WITH 2” HOLE FLASH

Page 5

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. - 13 -

Page 6

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. AOPS7483 Kit contents: Item Qty Concentric Vent 1 Flashing, sing

Page 7

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. INSTALLING CONCENTRIC VENT UTILIZING EXISTING ROOF JACK AS A CHASE.

Page 8

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. 8. Drop 3” pipe assembly (FIG-3) thru 4” flue opening of roof jack, s

Page 9

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. - 5 -

Page 10

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. INSTALLING CONCENTRIC VENT THRU THE ROOF USING 3” FLASHING PLATES. 1

Page 11

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. CARBON MONOXIDE POISONING, FIRE AND EXPLOSION HAZARD. Failure to fol

Page 12

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE P

Page 13

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. INSTALLING CONCENTRIC VENT KIT OUT SIDE WALL. 1. Determine best loc

Commentaires sur ces manuels

Pas de commentaire