THERMO PRODUCTS, LLC.
POST OFFICE BOX 217
NORTH JUDSON, IN 46366
PHONE: (574) 896-2133
MG-517
ECN 5396-MA 141211
MADE IN USA
GAS FIRED HIGH EFFICIENCY FURNACE
DOWNFLOW & DIRECT VENT (SEALED COMBUSTION)
MODELS:
CMA3-50D36N, CMA3-75D36N,
CMC1-50D36N, CMC1-75D36N,
CMC1-50DV3N, CMC1-75DV3N
INSTALLATION AND SERVICE MANUAL
For installation in:
1. Manufactured Homes
2. Modular Homes/Buildings
3. Site Constructed—Residential (Single Story Dwellings)
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
:
If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury, or loss of life.
: Improper installation, adjustment, alteration, service, or maintenance can cause injury or
property damage. Refer to this manual. For assistance or additional information, consult a qualified
installer, service agency, or fuel supplier.
: Do not use this appliance if any part has been underwater. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the electrical or control system
that has been underwater.
PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING
ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER AND SHOULD BE
RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL.
Vue de la page 0
1 2 3 4 5 6 ... 63 64

Résumé du contenu

Page 1 - ECN 5396-MA 141211

THERMO PRODUCTS, LLC. POST OFFICE BOX 217 NORTH JUDSON, IN 46366 PHONE: (574)

Page 2 -

All installations and services must be performed by qualified service personnel. 8MODEL CMC1-50D36 CMC1-75D36 INPUT IN BTUH 50,000 75,000 OUTPU

Page 3

All installations and services must be performed by qualified service personnel. 9MODEL CMC1-50DV3 CMC1-75DV3 INPUT IN BTUH 50,000 75,000 OUTPU

Page 4

All installations and services must be performed by qualified service personnel. 10 INSTALLATION PARTS PACKAGES PARTS PKG#

Page 5

All installations and services must be performed by qualified service personnel. 11 III. GENERAL INSTRUCTIONS AND CLEARANCES – READ BEFORE START OF

Page 6

All installations and services must be performed by qualified service personnel. 12 c. American National Standard (ANSI-Z223.1/NFPA-54) for all gas-

Page 7

All installations and services must be performed by qualified service personnel. 13 IV. GENERAL INSTALLATION A. FURNACE LOCATION 1. For best

Page 8

All installations and services must be performed by qualified service personnel. 14 Coil Cabinet Model: CE113S / CE213T Note: Coil cabinet c

Page 9 - II. FURNACE SPECIFICATIONS

All installations and services must be performed by qualified service personnel. 15 B. BASE INSTALLATION – CMA3 models only 1. Combustible Floo

Page 10

All installations and services must be performed by qualified service personnel. 16 After cutting openings in the floor, place the bottom panel in po

Page 11

All installations and services must be performed by qualified service personnel. 17 C. ALCOVE INSTALLATION In this application, a minimum of 18 in

Page 12 - INSTALLATION PARTS PACKAGES

TABLE OF CONTENTS SECTION BEGINNING PAGE I. SAFETY INFORMATION 1 II. FURNACE SPECIFICATIONS

Page 13

All installations and services must be performed by qualified service personnel. 18 CMA3 SERIES CMC1 SERIES Figure 5. : Do not obstr

Page 14

All installations and services must be performed by qualified service personnel. 19 8. Gas piping is not to be located in or through the return duc

Page 15

All installations and services must be performed by qualified service personnel. 20 hazardous situation. Dry moisture from all leads and terminals if

Page 16

All installations and services must be performed by qualified service personnel. 21 MAXIMUM VENT LENGTH VENT SIZE 2 IN. PVC FURNACE MODEL VENT L

Page 17

All installations and services must be performed by qualified service personnel. 22 G. CONNECTING THE EXHAUST VENT AND COMBUSTION AIR INTAKE Figure

Page 18

All installations and services must be performed by qualified service personnel. 23 the conclusion of the vent pipe installation. This will insure a

Page 19

All installations and services must be performed by qualified service personnel. 24 gas flame. Should acid compounds form in your furnace, it may red

Page 20

All installations and services must be performed by qualified service personnel. 25 b. The bottom edge of the vent termination elbow must b

Page 21

All installations and services must be performed by qualified service personnel. 26 • where wetting of components by condensate, or water vapor, cou

Page 22

All installations and services must be performed by qualified service personnel. 27 4. Vent Terminal Location Guidelines : Bushes, shrubs, or any v

Page 23

All installations and services must be performed by qualified service personnel. 1I. SAFETY INFORMATION This and the following page contain reprodu

Page 24

All installations and services must be performed by qualified service personnel. 28 Figure 10: Typical Construction Details of Sidewall Vent and Air

Page 25

All installations and services must be performed by qualified service personnel. 29 The furnace may be vented vertically through the roof. The outlet

Page 26

All installations and services must be performed by qualified service personnel. 30 CEILING: Frame out area around where PVC pipe is to penetrate ce

Page 27

All installations and services must be performed by qualified service personnel. 31 L. ELECTRICAL WIRING All wiring shall be performed by a qualifi

Page 28

All installations and services must be performed by qualified service personnel. 32 IMPORTANT: The room thermostat should be installed 4 to 5 feet

Page 29

All installations and services must be performed by qualified service personnel. 33 4. BLOWER MOTOR SPEED WIRING Figure 15. BLOWER DELAY SETTI

Page 30

All installations and services must be performed by qualified service personnel. 34 CMA3-50D36 ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PR

Page 31

All installations and services must be performed by qualified service personnel. 35 CMA3-75D36 ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PR

Page 32

All installations and services must be performed by qualified service personnel. 36 CMC1-50D36 ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRE

Page 33

All installations and services must be performed by qualified service personnel. 37 CMC1-75D36 ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PR

Page 34

All installations and services must be performed by qualified service personnel. 2This and the previous page contain reproductions of the various saf

Page 35 - Figure 15

All installations and services must be performed by qualified service personnel. 38 CMC1-50DV3 ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRE

Page 36 - CMA3-50D36

All installations and services must be performed by qualified service personnel. 39 CMC1-75DV3 ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PR

Page 37 - CMA3-75D36

All installations and services must be performed by qualified service personnel. 40 : TURN OFF THE ELECTRICAL POWER to the furnace before attempting

Page 38 - CMC1-50D36

All installations and services must be performed by qualified service personnel. 41 V. STARTING THE UNIT A. SEQUENCE OF OPERATIONS STARTTRIALF

Page 39 - CMC1-75D36

All installations and services must be performed by qualified service personnel. 42 MAINBURNEROPERATIONENDOF CYCLECALLFORHEATSATISFIEDAFTER DELAY-

Page 40 - CMC1-50DV3

All installations and services must be performed by qualified service personnel. 43 B. INITIAL START UP: This furnace does not have a pilot. It

Page 41 - CMC1-75DV3

All installations and services must be performed by qualified service personnel. 44 C. ADJUSTMENT OF BTU INPUT RATE: The orifice for this furnace

Page 42

All installations and services must be performed by qualified service personnel. 45 GAS PRESSURE CHART FOR CMA*/CMC* MODEL FURNACES TABL

Page 43 - A. SEQUENCE OF OPERATIONS

All installations and services must be performed by qualified service personnel. 46 Figure 16. : The CMA/CMC furnace models are direct vent design

Page 44

All installations and services must be performed by qualified service personnel. 47 F. FURNACE CHECKOUT PROCEDURE Before any system of gas p

Page 45

All installations and services must be performed by qualified service personnel. 3This and the previous page contain reproductions of the various saf

Page 46

All installations and services must be performed by qualified service personnel. 48 VI. INSTALLER'S INSTRUCTIONS TO USER: After completing t

Page 47

All installations and services must be performed by qualified service personnel. 49 : Label wires prior to disconnection when servicing controls. Wir

Page 48

All installations and services must be performed by qualified service personnel. 50 necessary, clean the accessible portions of the housing and blowe

Page 49

All installations and services must be performed by qualified service personnel. 51 assure proper furnace operation. Follow the cleaning, removal and

Page 50

All installations and services must be performed by qualified service personnel. 52 If the sensed failure is in the system (external to the control),

Page 51

All installations and services must be performed by qualified service personnel. 53 TURN THERMOSTAT TO CALL FOR HEATDOES THERMOSTAT MAKE CONTACT?IS

Page 52

All installations and services must be performed by qualified service personnel. 54 CHECK WIRING TO INDUCERAND IF OK, REPLACEINDUCER ASSEMBLY.AFT

Page 53

All installations and services must be performed by qualified service personnel. 55 CHECK FOR PROPERMANIFOLD PRESSURE.NoYesYesYesAFTER GAS VALVEOPENS

Page 54

All installations and services must be performed by qualified service personnel. 56 DOES SYSTEM RUN UNTILTHERMOSTAT IS SATISFIED?CHECK ALLWIRING F

Page 55

All installations and services must be performed by qualified service personnel. 57 YesTROUBLESHOOTING COMPLETE.YesIF LED LIGHT FLASHES:1 FLASH, THEN

Page 56

All installations and services must be performed by qualified service personnel. 4The following safety information should be read, understood,

Page 57

All installations and services must be performed by qualified service personnel. 58 APPENDIX – A REPLACEMENT PARTS

Page 58

All installations and services must be performed by qualified service personnel. 59

Page 59

All installations and services must be performed by qualified service personnel. 60

Page 60

All installations and services must be performed by qualified service personnel. 61

Page 61

All installations and services must be performed by qualified service personnel. 62 APPENDIX – B WIRING DIAGRAMS

Page 62

All installations and services must be performed by qualified service personnel. 5: The vent and air intake elbows must be kept away from bushes, shr

Page 63

All installations and services must be performed by qualified service personnel. 6: Copper and brass tubing and fittings (except tin lined)

Page 64

All installations and services must be performed by qualified service personnel. 7II. FURNACE SPECIFICATIONS MODEL CMA3-50D36 CMA3-75D36 INPUT I

Commentaires sur ces manuels

Pas de commentaire